Connecting the Antenna Cables
RoamAbout Antenna Site Preparation and Installation Guide 3-35
Using The Male Pigtail
Figure 321andFigure 322showthecableconfigurationsforusingamalepigtailconnectorto
connectanAPtoanoutdoorantenna.
Figure 321showstheconfiguration forusingaLightningProtector.Figure 322showsthe
configurationwhennotusingaLightningProtector.Table 317describestheconfigurations.
Figure 3-21 Male Pigtail Cable With Lightning Protector
Figure 3-22 Male Pigtail Cable Without Lightning Protector
Table 3-17 Male Pigtail Cable Components
# Component Connectors
1 RoamAbout pigtail connection (50 cm) - Male Right Angle MC Card to AP
Reverse-N Male to antenna
Male connector housing and male
center contact.
2 Low-loss antenna cable
(lengths of 20, 25, 50 or 75 feet)
Reverse-N Female on both ends
Female connector housing and female
center contact.
3 Lightning protector Reverse-N Male on both ends
Male connector housing and male center
contact.
4 Low-loss antenna cable
(lengths of 20, 25, 50 or 75 feet)
Reverse-N Female on both ends
Female connector housing and female
center contact.
5 Outdoor antenna cable Reverse-N Male
Male connector housing and male center
contact.
1
2 3 4
5
1
4
5
Zobrazit stránku 66