Physical Specifications
RBT-8200 Wireless Switch Installation Guide 1-5
Physical Specifications
ThephysicalspecificationsfortheRBT8200 WirelessSwitcharelistedinTable 13.
Environmental Requirements
EnsurethattheenvironmentalrequirementsarewithintherangesdescribedinTable 14.
Table 1-3 Physical Specifications
Parameter Approximate Specification
Width 430 mm (16.93 in.)
Height 87.5 mm (3.445 in.)
Depth 672 mm (26.457 in.)
Table 1-4 Environmental Specifications
Parameter Description
Operating Temperature 10°C to 35°C (50°F to 95°F) with the maximum rate of change not to
exceed 10°C per hour
Non-Operating Temperature 40°C to 70°C (104°F to 158°F)
Altitude -60 meters (-197 feet) below sea level to 4000 meters (13,123 feet)
above sea level
Non-Operating humidity 90%, non-condensing @ 35°C (95°F)
Acoustic noise Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office
ambient temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical office ambient
temperature. (23 +/- 2 degrees C)
Operating Shock No errors with a half sine wave shock of 2G (with 11 millisecond
duration).
Package Shock Operational after a 24 -inch free fall, although cosmetic damage may
be present (chassis weight 40-80 lbs)
ESD +/-15kV per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
1826 BTU/hour